PowerFlex 525 AC drives operate at temperatures as high as 70 C (158 F), and they are ideal for applications such as conveyors, fans, pumps, and mixers. This series of drives are available in power ratings from 0.25 to 15 Horsepower and they support multiple voltage classes including 120, 240, 480, and 600 Volts AC. Parameter Speed Ref Select (7) in conjunction with Local/Remote selector switch is used to define the speed command input Speed Command In (276).When the selector PowerFlex 40 with Comms card with Comms card PowerFlex 40 with Comms card. Allen-Bradley PowerFlex 40 Manual Online: Integral Keypad. Verify that ambient temperature has not exceeded 40C (104F) for IP 30/NEMA 1/UL Type 1 installations or 50C (122F) for Open type installations. The C128 value tells you how the IP address is set. PowerFlex 4 AC Drive 0.23.7 kW; If the IP address is set by BootP, the value displayed will be a 2.

120 mm (4.7 in.) Allen-Bradley PowerFlex 523 Manual Online: Advanced Program Group Parameters. Check for excess load, improper DC boost setting, DC PowerFlex 4 and 40 Technical Data 4 Publication 22-TD001G Optimized Performance Removable MOV to ground provides trouble-free operation when used on ungrounded distribution systems. The Dig In Status is the parameter that holds the status of the digital input we have tied our push-button to. PowerFlex 4M Technical Data 3 Start Up, Programming and Operation An integral keypad provides out of the box operation using the local potentiometer and control keys. Step 3.3 - For Input Data Choose Dig In Status. Display Group Parameters No. 2-2 Start Up PowerFlex 40 Adjustable Frequency AC Drive FRN 1.xx - 6.xx User Manual Publication 22B-UM001H-EN-E Applying Power to the Drive 6. 3-59. PowerFlex 4 and PowerFlex 40 AC Drives Provide Optimized Simplicity Providing users with powerful motor speed control, the Allen-Bradley PowerFlex 4 and PowerFlex 40 AC drives are ideal for machine level speed control and provide the application versatility to meet the demands of global OEMs and end users requiring flexibility, space savings and ease of use. Minimum Maximum Clearances -10C (14F) 40C (104F) IP 20/Open Type Use Mounting Option A IP 30/NEMA 1/UL Type 1(1) (1)Rating requires installation of the PowerFlex 40 IP 30/NEMA 1/UL Type 1 option kit. Integral brake transistor, available on all ratings (except no brake version), provides dynamic braking capability with simple low cost brake resistors. By having this parameter in the Input Data section, the drive will send the appropriate information to the PLC. 40C (104F) IP 20/Open Type Use Mounting Option A IP 30/NEMA 1/UL Type 1(1) (1) Rating requires installation of the PowerF lex 4 IP 30/NEMA 1/UL Type 1 option kit. This chapter provides a complete listing and description of the PowerFlex 525. parameters. PowerFlex 40 Adjustable Frequency AC Drive FRN 1.xx - 7.xx User Manual Publication 22B-UM001I-EN-E In this manual we refer to the PowerFlex 40 Adjustable Frequency AC Drive as; drive, PowerFlex 40 or PowerFlex 40 Drive. Then using the up/down arrows, scroll through to find C128. C123. The PowerFlex 4 is designed so that start up is simple and efcient. The Program Group contains the most commonly used parameters. Smart Start-Up with Basic Program Group Parameters = Stop drive before changing this parameter. No. Parameter Min/Max Display/Options Default P031 [Motor NP Volts] 20/Drive Rated Volts 1 VAC Based on Drive Rating Selects velocity-specific or position/fibers-specific Command. The Program Group contains the most commonly used parameters. NEMA 250 - Enclosures for Electrical Equipment built-in keypad, RSLogix 5000 version 17.0 or greater, Logix Designer version. 1. Step 2: Determining Where the IP Address is Set Once you have found the C, press Enter. Reference page page g-go page a-ao Parameter P036 [Start source] P038 [Speed Reference] A103 [Comm Data Rate] A104 [Comm Node Addr] Details Set to 5 "RS485 (DSI) Port" if Start is controlled from the network. It will either be set by BootP or by Parameters. 120 mm (4.7 in.) the main features of the powerflex40 ac drive are: integral keypad for simple operation and programming, 4 digit display with 10 led indicators for display of drive status, communication with pc using the rs-485 interface, ethernet/ip (also devicenet, profibus dp, lonworks and controlnet interface are available), autotune allows the current set by parameter P033 [Motor OL Current]. Premier Integration with PowerFlex AC drives uses the Logix control platform to simplify parameter and tag programming and reduces development time. and Status Word bit definitions for use over a communication. 40. PowerFlex, DriveExplorer, DriveExecutive, PLC, Force Technology, DPI, and SCANport are either trademarks or registered [Param Access Lvl] description expanded. Position 1-3 4 5 6-8 9 101112131415 16+ 23B D 4P0 D 1 0 4 N N P6 abcdefghij a Drive Code Type 23B PowerFlex 40 b Voltage Rating Code Voltage Ph. Page 8: Manual Conventions. 7. 120 mm (4.7 in.) Chevron Down. The PowerFlex 40 drive can be used for Volts per hertz or Sensorless Vector applications and offers an Autotune feature allowing the drive to adapt to individual motor characteristics. Preset Freq 6 = 50.00 Hz. As the names suggest, parameters within a section will address the setup of electrical parameters, communication with other devices, logical programming and the display of the drive. Aotewell Ltd www.aotewell.com Industry Automation Overview Manual Conventions In this manual we refer to the PowerFlex 40 Adjustable Frequency AC Drive as; drive, PowerFlex 40 or PowerFlex 40 Drive. Parameters are programmed (viewed/edited) using either the drive's. The PowerFlex 40 is designed so that start up is simple and efcient. Get Support Distributor. PowerFlex 525 3-48 Parameter 366 [Digital In6 Sel] is no longer changeable. F12 HW OverCurrent(1) Check programming. These drives feature sensorless vector control to meet low-speed torque demands. In addition, the PowerFlex 40 AC drive features sensorless approach simplifi es parameter and tag programming while still allowing stand-alone drive software tool use on the factory fl oor. The following is a listing of the possible fault codes of the Allen Bradley PowerFlex 40 drive and short descriptions of the causes. Functional Description 1-3 7000-TD002E-EN-P June 2013 Speed Command The function of Speed Command block is to select one of the 10 possible speed command inputs. Overview. Programming and Parameters. Apply AC power and control voltages to the drive. Preset Freq 5 = 40.00 Hz. RUN FWD REV PROGRAM No. Parameter Min/Max Display/Options d001 [Output Freq] 0.0/[Maximum Freq] 0.1 Hz d002 [Commanded Freq] 0.0/[Maximum Freq] 0.1 Hz d003 [Output Current] 0.00/Drive Amps 2 0.01 Amps See the PowerFlex 520-Series Adjustable Frequency AC Drive User Manual, publication descriptions of the parameters listed here, as well as the full list of available parameters. Standard Features This package integrates the Standard PowerFlex 40 drive. See the PowerFlex 40 User Manual on CD for more information on parameters. PowerFlex 40 - AC Drives. 200240V: 0.23.7 kW / 0.255 Hp / 1.417.5 A. Ambient temperatures up to 50 C (122 F) permitted with minimal spacing between drives. we learn by this video,how to set the parameters in drive, how to enter in program mode. Check fan. F3 Power Loss DC bus voltage is below 85% of nominal. 0. The full list of the DeviceNet Adaptor Cards features follows, as pulled from the cards User Manual, publication #520COM-UM002A-EN-E, dated April 2013: Mounting onto a PowerFlex 525 [and 523] Control Module back cover for installation into the drive. Catalog Number Explanation The PowerFlex 40 Adjustable Frequency AC Standard Configured Drives catalog numbering scheme is shown below.

Preset Freq 715 = 60.00 Hz. established through the communication adapter or the drive's. The PowerFlex 40 AC drive shares all the same features and functionality of the PowerFlex 4 AC drive. Use Mounting Option B 50C (122F) IP 20/Open Type Use Mounting Option B F8 Heatsink OvrTmp(1) Check for blocked or dirty heat sink ns. PowerFlex 40 / 40P / 400 No Yes Yes if IP set Yes Yes PowerFlex 70 / PF70EC / 700std / 700H Yes Yes Yes if IP set Yes Yes PowerFlex 700VC Yes Yes Yes if IP set Yes Yes 1. Parameter Configuration The following PowerFlex 40 parameters are used to configure the drive to operate on a network. F2 Auxiliary Input Auxiliary input interlock is open. network. [Stp Logic 0-7] 0001/bAFF 4 Digits For a list of digit options, refer to the PowerFlex 40 The PowerFlex 40 series AC drives are some of the most compact AC drives available from Allen-Bradley. This parameter cannot be changed when an I/O connection is. This video provide you the basic understanding for control wiring and programming for allean Bradly powerflex 40 VFD & PowerFlex 4 VFD. Options 1English (Default) 2Franais 3Espaol 4Italiano 5Deutsch 6Reserved 7Portugus 8Reserved 9Reserved 10Nederlands 22B-UM001.book Page 32 Tuesday, May 30, 2017 5:22 PM Programming and Parameters3-33 PowerFlex 40 Adjustable Frequency AC Drive FRN 1.xx - 7.xx User Manual Publication 22B-UM001I-EN-E

Find a Product Partner Orders. 120 mm (4.7 in.) PowerFlex 40 AC Drives provide OEMs, machine builders, and end users with performance-enhancing motor control in an easy-to-use compact package. 3-40 Parameter 238 [Fault Config 1] footnote 3 added. Make a connection via the serial point to point connection, and select the 22-COMM-E parameter list 2. Programming and Parameters 3-9 PowerFlex 40 Adjustable Frequency AC Drive FRN 1.xx - 6.xx User Manual Publication 22B-UM001H-EN-E Basic Program Group P031 [Motor NP Volts] Related Parameter (s): d004, A084, A085, A086, A087 Stop drive before changing this parameter. Set to the motor nameplate rated volts. They include multiple control and hardware options, as well as optional embedded safety features. Contact a Distributor Find A Sales Office Support. 21.0 or greater, or Connected Components Workbench version 3.0 or greater. PowerFlex 40 Sample Specification GENERAL REFERENCES Designed to meet the following specifications: NFPA 70 - US National Electrical Code NEMA ICS 3.1 - Safety standards for Construction and Guide for Selection, Installation and Operation of Adjustable Speed Drive Systems. D 480V ac 3 c Amp Rating 480V 60Hz Input Code Amps kW (Hp) 1P4 1.4 0.4 (0.5) With flexible enclosure options, and simple programming, they can be installed and configured quickly. These drives feature sensorless vector control to meet low-speed torque demands. A relay pre-charge limits inrush current. Click on the information icon , and then the EtherNet Settings tab. The cause of the fault will have to be corrected before the fault can be reset and the drive started. Optional IP30 NEMA/UL Type 1 enclosure conversion kit. 22B PowerFlex 40 Overview Power ratings: 100120V: 0.41.1 kW / 0.51.5 Hp / 2.36 A 200240V: 0.47.5 kW / 0.510 Hp / 2.333 A 380480V: 0.411 kW / 0.515 Hp / 1.424 A 500600V: 0.7511 kW / 115 Hp / 1.719 A IP20 NEMA/UL Type Open, plate drive, flange mount, IP66 NEMA/UL Type 4X/12, and DIN rail Controlling PowerFlex 525 Drives over EtherNet IP. PowerFlex 40 AC Drives provide OEMs, machine builders, and end users with performance-enhancing motor control in an easy-to-use compact package. The 12 most common application parameters are contained in the Basic Program Group, making programming fast and easy. 3-48 Parameter 242 [Power Up Marker] description expanded. Chapter 4 provides information to guide you in troubleshooting the PowerFlex 40 drive. Included is a listing and description of drive faults (with possible solutions, when applicable). The condition or state of your drive is constantly monitored. Zero Stacking Drives for ambient temperatures up to 40 C (104 F) Configuration and programming via integral LCD keypad, remote keypad, or software. Create and save custom parameter groups using the CustomView tool. PowerFlex 525 - Module Definition Input Data. LED Run/Direction Status Alphanumeric Display Displayed Units Steady Red Program Status Steady Red Fault Status Pot Status Start Key Status Steady Green No. embedded EtherNet/IP port. These drives are well-suited for a wide variety of motor control applications including pumps, fans, and conveyors. It receives the required power from the drive and from the DeviceNet network. For further information visit: www.abpowerflex.com or www.ab.com/support/abdrives Performance Mounting Option A Supports PowerFlex drives, Micro800 controllers and PanelView component graphic terminals. The programming keys have the same function as all other PowerFlex 380480V: 0.43.7 kW / 0.55 Hp / 1.48.7 A. IP20 NEMA/UL Type Open, plate drive, flange mount, and DIN rail. Chevron Down. Familiarize yourself with the integral keypad features (see page 2-4) before setting any Program Group parameters. Use Mounting Option B 50C (122F) IP 20/Open Type Use Mounting Option B 25 mm (1.0 in.)